Technical data
Control range
Lifetime
Maintenance-free in pure ambient air
40 ... 90 % RH
ca. 6.000 breaking cycles
Ohmic load, dehumidification 0.1...5A
Ohmic load, humidification 0.1...2A
Inductive load 0.1...1A (power factor >0.8)
1...100 mA
HM120 Hygro Modul
Humidity-dependent switch suitable for installation in devices
Features
- OEM version
- Accuracy: ±3,5 % RH
- Robust
- Long-term stability
- Washable Polyga® measuring element
- High accuracy in the high humidity range
- No external power supply required
The hygro module HM120 is a humidity-dependent switch that can be fitted in equipment such as hygrostats, humidifiers, dehumidifiers, ventilating fans, driers and many more. The module represents an on-off controller with changeover contact. The switch connection is via a connecting terminal, but can also be supplied ready-made with cable connections. Protection of the module is of the IP00 type.
Remarkably straightforward and durable design
Our Humidistats feature a simple and robust design. The Polyga® measuring element is a unique hygroscopic fibre that changes its length depending on the humidity. The changes in length of the POLYGA® fibres are transferred via a lever system to a microswitch, resulting in an on/off controller that needs no auxiliary power supply.
Waterresistent and maintenance-free
It has unparalleled long-term stability and is 100 % waterproof, which makes it ideal for use in high humidity. In pure ambient air the measurement element is maintenance-free.