Galltec-Mela logo Humidity measuring technology - high quality

Technical data

Relative Humidity
0...100 % RH
SVKA.00
SVKA.11
SVKA.0D
-40 ... + 85 °C
optionally ammonia-resistant
optionally pressure-resistant up to 10bar
SVKA.0E
SVKA.1E
SVKA.ED
-50 ... + 150 °C
optionally ammonia-resistant
optionally pressure-resistant up to 10bar
Can be combined with transmitterhead
AW (wallmount)
AK (ductmount)
Standard cable length
1,5 m

S series SVKA probes

Humidity and temperature probes to be combined with transmitterhead AW or AK

Features

  • Operating temp. up to 85 °C
  • Accuracy: ±1,5 % RH
  • On-site calibration
  • IP65
  • Stainless steel sensor tube
  • Modular, can be combined

Options

  • Pressure-resistant up to 10 bar
  • Ammonia-resistant

Industry Transmitters for humidity and temperature, the A-series probe and transmitter are interchangeable and can be combined in any combination; they can be used at temperatures up to 85 °C in non-corrosive air. Optionally pressure-resistant up to 10 bar.

SVKA.00 -40…80 °C
SVKA.0E -50…150 °C
The scope of delivery includes the sintered high-grade steel filter ZE13. If a better dynamics should be required, we recommend to use the filter type ZE04 together with a PTFE filter.

Transmitter der A-Serie
The integrated hx processor can calculate further humidity values and apply them to the two outputs. With the RS485 standard all of the hx-values can be read simultaneously. Due to the digitisation of signal processing, the measurement accuracy for humidity achieves excellent values of ±1.5 % RH. In temperature measurement, the platinum resistance sensor achieves tolerances of ±0.15 K..

Often used in

  • Agriculture & food industry
  • Chemical industry
  • Clean rooms
  • Climate chambers
  • Drying plants
  • Paint shops
  • Paper & print
  • Pharmaceutical industry
  • Process and factory automation